From efa7f2c83735109013f78f61d3abde6e53dd594b Mon Sep 17 00:00:00 2001 From: 12451 <12451@example.com> Date: Thu, 2 Jul 2026 17:01:45 +0800 Subject: [PATCH] =?UTF-8?q?docs:=20pow=5Ffail=E5=A2=9E=E5=8A=A0info?= =?UTF-8?q?=E5=AD=97=E6=AE=B5=E5=8C=BA=E5=88=86=E4=BA=A4=E7=9B=B4=E6=B5=81?= =?UTF-8?q?=E5=81=9C=E7=94=B5=EF=BC=8Cpow=5Fon/pow=5Foff=E7=8B=AC=E7=AB=8B?= =?UTF-8?q?=E4=B8=BA=E5=B9=B3=E5=8F=B0=E4=B8=8B=E5=8F=91=E6=8C=87=E4=BB=A4?= MIME-Version: 1.0 Content-Type: text/plain; charset=UTF-8 Content-Transfer-Encoding: 8bit --- AGENTS.md | 25 +++++++++++++++++++++---- 1 file changed, 21 insertions(+), 4 deletions(-) diff --git a/AGENTS.md b/AGENTS.md index 5ab4f60..c8c0594 100644 --- a/AGENTS.md +++ b/AGENTS.md @@ -439,23 +439,40 @@ operation_log(操作日志) - value: 6个通道状态拼接(每通道2字节=4个HEX字符) - 平台从key解析仓控板数量 -### pow_fail/pow_on/pow_off格式 +### pow_fail格式 ```json { "act": "pow_fail", "msg_id": 15, + "dev_id": "123456789012345", + "info": "0" +} +``` + +**字段说明:** +- `act` — 指令类型:`pow_fail` +- `msg_id` — 自增会话ID +- `dev_id` — 设备IMEI +- `info` — 停电类型:`0`=直流停电(12V掉电),`1`=交流停电(380V掉电) + +**pow_fail**:柜控板检测到电源掉电时上报。直流停电(12V)时设备切换到后备电池供电,仍可远程通讯;交流停电(380V)时充电电源不可用。 + +### pow_on/pow_off格式 + +```json +{ + "act": "pow_on", + "msg_id": 16, "dev_id": "123456789012345" } ``` **字段说明:** -- `act` — 指令类型:`pow_fail`(12V掉电上报)、`pow_on`(接触器合闸)、`pow_off`(接触器分闸) +- `act` — 指令类型:`pow_on`(接触器合闸)、`pow_off`(接触器分闸) - `msg_id` — 自增会话ID - `dev_id` — 设备IMEI -**pow_fail**:柜控板检测到12V电源掉电时上报,设备切换到后备电池供电,仍可远程通讯。 - **pow_on**:平台下发合闸指令,柜控板吸合接触器恢复380V充电电源供电。 **pow_off**:平台下发分闸指令,柜控板断开接触器切断380V充电电源供电。