docs: 删除重复的格式章节,统一放在指令详情中

This commit is contained in:
12451 2026-07-02 17:24:16 +08:00
parent 34f591a9b8
commit 9581730d56

View File

@ -419,63 +419,6 @@ operation_log(操作日志)
| `pow_off` | 平台→设备 | `IMEI` | 接触器分闸切断380V供电 | | `pow_off` | 平台→设备 | `IMEI` | 接触器分闸切断380V供电 |
| `reset` | 平台→设备 | `IMEI``IMEI-仓控板` | 重启整柜或仓控板 | | `reset` | 平台→设备 | `IMEI``IMEI-仓控板` | 重启整柜或仓控板 |
### status_post格式
```json
{
"act": "status_post",
"msg_id": 42,
"dev_id": "123456789012345",
"rssi": 85,
"status": {
"123456789012345-01": "000100020003000400050006",
"123456789012345-02": "000100020003000400050006"
}
}
```
- key: `IMEI-仓控板ID`
- value: 6个通道状态拼接每通道2字节=4个HEX字符
- 平台从key解析仓控板数量
### pow_fail格式
```json
{
"act": "pow_fail",
"msg_id": 15,
"dev_id": "123456789012345",
"info": "0"
}
```
**字段说明:**
- `act` — 指令类型:`pow_fail`
- `msg_id` — 自增会话ID
- `dev_id` — 设备IMEI
- `info` — 停电类型:`0`=直流停电(12V掉电)`1`=交流停电(380V掉电)
**pow_fail**:柜控板检测到电源掉电时上报。直流停电(12V)时设备切换到后备电池供电,仍可远程通讯;交流停电(380V)时充电电源不可用。
### pow_on/pow_off格式
```json
{
"act": "pow_on",
"msg_id": 16,
"dev_id": "123456789012345"
}
```
**字段说明:**
- `act` — 指令类型:`pow_on`(接触器合闸)、`pow_off`(接触器分闸)
- `msg_id` — 自增会话ID
- `dev_id` — 设备IMEI
**pow_on**平台下发合闸指令柜控板吸合接触器恢复380V充电电源供电。
**pow_off**平台下发分闸指令柜控板断开接触器切断380V充电电源供电。
### 指令详情 ### 指令详情